Breville Infuser Leaking Water? 5 Fixes (BES840)

leaks water flow
August 19, 2026
13 minutes
DIY Repair

Water escaping from the group head, or steam venting where it shouldn't? The Infuser's older internal design leaks differently than newer Breville models.

An Older Design With Its Own Leak Pattern

The Infuser has been in Breville's lineup longer than the Barista Express, and its group head assembly is built a little differently — which means some of its leak points don't match what you'll read in guides written for the newer models. Steam occasionally escaping from the group head instead of the wand, or the hot water dispenser routing water through the wrong path, are patterns specific enough to this machine that they're worth calling out directly rather than treating every leak as a simple gasket problem.


Quick Checks (2 Minutes)

  • Dry the machine completely, pull a shot, and watch closely for where water first appears
  • Check the portafilter lock — does it click firmly into place, or does it feel loose?
  • Empty and reseat the drip tray, pushing until it's fully seated
  • Watch what happens during steaming specifically — leaks that only show up here point to a different cause than brewing leaks

Fix 1: Replace or Reseat the Group Head Gasket (Works 34% of Time)

Symptoms:

  • Water sprays or drips from around the portafilter during extraction
  • Portafilter locks further past its usual stopping point than it used to
  • Machine has seen regular daily use for a year or more

How to Fix:

  1. Remove the portafilter and look up into the group head at the rubber gasket ring
  2. Check its condition — flattened, hardened, or cracked all mean it's worn
  3. If it's just dirty, soak it in hot water for 10 minutes and reinstall
  4. If worn, replace it — the Infuser uses the same 54mm gasket as the Barista Express, not the smaller Bambino size
  5. Press the new gasket in firmly around its full circumference
  6. Reinstall the portafilter and test with a shot

Time: 10-15 minutes Cost: Free (cleaning) or $6-12 (new gasket) Success Rate: 34% Difficulty: Easy

If this doesn't work: Move to Fix 2 — steam escaping from the group head points somewhere different entirely.


Fix 2: Steam or Hot Water Coming From the Group Head Instead of the Wand (Works 24% of Time)

Symptoms:

  • Steam vents from the group head area when you engage the steam wand
  • Using the hot water dispenser sends water out through the group head, not the spout
  • Happens intermittently, often worse once the machine's fully warmed up

How to Fix:

  1. Unplug the machine and let it cool completely — this involves internal valve components
  2. This pattern usually points to the internal diverter valve not fully switching between brew, steam, and hot water modes
  3. Run each function (brew, steam, hot water) separately several times in a row to see if repeated cycling clears a temporarily stuck valve
  4. Descale fully — mineral buildup around the valve seat is a common cause of it not seating correctly
  5. If the issue persists after descaling and repeated cycling, the valve itself likely needs professional replacement — this isn't a simple DIY part swap on this model

Time: 20-30 minutes to diagnose Cost: Free (descaling) or professional repair if the valve needs replacing Success Rate: 24% Difficulty: Moderate

If this doesn't work: Check Fix 3 for a more serious internal cause.


Fix 3: Thermocoil Crack Causing a Base Leak (Works 16% of Time)

Symptoms:

  • Water leaks from underneath the machine specifically during extraction, not while idle
  • Leak seems to originate from deep inside rather than any external seal
  • Machine is several years old with heavy daily use

The Infuser heats water through a thermocoil rather than a traditional boiler, and after years of heat cycling, hairline cracks can develop. This isn't something to attempt yourself — confirming a thermocoil crack requires opening the machine, and replacement is a job for a technician. If your leak only appears during active extraction and none of the external checks above explain it, this is worth ruling in before assuming a cheaper cause.

Time: N/A (professional diagnosis required) Cost: $80-150 for thermocoil or pump replacement Success Rate: 16% Difficulty: Professional

If this doesn't work: Try Fix 4 for the more common drip tray and tank causes first, if you haven't already.


Fix 4: Drip Tray and Water Tank Seal (Works 15% of Time)

Symptoms:

  • Puddle forms under or behind the machine, not tied specifically to brewing
  • Drip tray was recently removed for cleaning
  • Tank feels slightly loose when reinserted

How to Fix:

  1. Pull the drip tray fully out, empty it, and check the drainage opening at the back of the slot for a popped-loose tube
  2. Reinstall the tray, pushing until it seats completely — a half-inserted tray is one of the most overlooked causes of a "mystery" leak
  3. Remove the water tank and inspect the O-ring seal at its outlet for cracking or flattening
  4. Clean both the O-ring and the machine-side receptacle of any mineral crust
  5. Reinsert the tank firmly and dry the area completely before checking again 10 minutes later

Time: 10 minutes Cost: Free (cleaning) or $5-8 (O-ring replacement) Success Rate: 15% Difficulty: Easy


When DIY Won't Work

Contact Breville support (1-866-273-8455) if:

  • All four fixes are exhausted and water still appears
  • You suspect a thermocoil crack or diverter valve failure (Fix 2 or Fix 3)
  • The machine is under warranty and the leak started without an obvious cause
  • You notice an electrical smell or the machine trips a breaker

Repair vs. replace: The Infuser typically retails for $400-500. Gasket and O-ring repairs under $15 are always worth doing yourself. A professional thermocoil or valve repair in the $80-150 range is still usually worth it on a machine this price, but on a unit past 5-6 years old with other issues stacking up, weigh that cost against replacement.


Prevention Tips

  • Replace the group head gasket every 12 months regardless of visible wear
  • Descale every 2-3 months — scale buildup is directly linked to both the group head gasket and the diverter valve failing early
  • Cycle brew, steam, and hot water modes occasionally even on days you only use one, to keep the diverter valve moving freely
  • Empty the drip tray daily and push it fully home every time
  • Don't overtighten the portafilter — firm is enough, excess force accelerates gasket wear

FAQ

Why does steam come out of my Infuser's group head instead of the wand?

This points to the internal diverter valve not switching modes cleanly, usually from mineral buildup around the valve seat. Try cycling each function several times after a full descale before assuming it needs replacement.

Is the Infuser's group head gasket the same size as the Barista Express?

Yes — both use a 54mm gasket, unlike the smaller Bambino models. Double-check the size when ordering a replacement so you don't end up with the wrong part.

How do I know if it's a thermocoil crack versus a simple gasket leak?

Timing is the key signal. A gasket leak shows up right at the portafilter during extraction. A thermocoil crack tends to leak from underneath the machine specifically during active brewing, and doesn't respond to any of the external fixes above.

Can descaling fix a leak on its own?

Sometimes, particularly if scale buildup is preventing the diverter valve from seating correctly. It won't fix a cracked thermocoil, a worn gasket, or a damaged O-ring — those need physical repair regardless of scale.

My Infuser only leaks when I use the hot water dispenser. What's going on?

That's a strong sign of the same diverter valve issue covered in Fix 2 — water is being routed through the wrong internal path. Descaling and cycling the functions repeatedly is the first thing to try before assuming a valve replacement is needed.

Is this leak pattern common on other Breville models too?

The group head gasket and drip tray issues are common across most Breville espresso machines. The diverter valve and thermocoil-specific patterns described here are more particular to the Infuser's older internal design than to newer models like the Barista Express.


Did this fix work for you?

24 people found this guide helpful

James Whitfield

James Whitfield

Lead Coffee Equipment Specialist

James spent seven years repairing and servicing commercial espresso machines before moving into consumer coffee maker troubleshooting. He has personally diagnosed and repaired over 300 coffee makers across Breville, DeLonghi, Jura, and Gaggia, and leads the testing process for all guides on this site.

Espresso machine pressure systemsGrinder mechanismsHeating element diagnostics

Related Articles

Continue your wellness journey with these hand-picked articles

Popular Articles

6 articles

Never fight a broken coffee maker alone

Weekly fixes, maintenance tips, and early guides — straight to your inbox. Free, forever.

No spam. Unsubscribe any time.